· Luminous Inverter Batteries are supplied fully charged & ready to use.

· Batteries stored for more than 45 days will require freshening charge/bench charge at the constant current, finishing rate as given in application chart. Charging to be continued till free gassing is observed and voltage & specific gravity reaches a constant value (around 16 volts/not less than 15.5 volts on charge) in three consecutive hourly readings.

· Ensure that the inverter does not allow a constant charging voltage above 13.5 volts after the battery is fully charged. Inverter should cut off discharge at 10.8/11 volts.